E Series Multifunction DAQ –
20 kS/s, 16-Bit, 16 Analog Inputs
255
National Instruments • Tel: (800) 433-3488 Fax: (512) 683-9300 [email protected] ni.com
E Series DAQ Devices
Measurements
Table 2. NI 601xE Analog Input Accuracy Specifications
Absolute Accuracy Relative Accuracy
Nominal % of Reading Offset Noise + Quantization (µV) Temp Absolute Accuracy Resolution (µV)
Range (V) 24 Hrs 90 Days 1 Year (
µ
V) Single Pt. Averaged Drift (%/°C) at Full Scale (mV) Single Pt. Averaged
±10.0 0.0058 0.0078 0.0100 397.2 526.4 45.8 0.0002 1.443 602.7 60.3
±5.0 0.0208 0.0228 0.0250 200.6 263.2 22.9 0.0007 1.474 301.4 30.1
±1.0 0.0208 0.0228 0.0250 43.3 52.6 4.6 0.0007 0.298 60.3 6.0
±0.1 0.0408 0.0428 0.0450 7.9 8.4 0.7 0.0012 0.054 9.6 1.0
0 to 10 0.0058 0.0078 0.0100 244.6 263.2 22.9 0.0002 1.268 301.4 30.1
0 to 5 0.0208 0.0228 0.0250 124.3 131.6 11.4 0.0007 1.386 150.7 15.1
0 to 1 0.0208 0.0228 0.0250 28.1 26.3 2.3 0.0007 0.280 30.1 3.0
0 to 0.1 0.0408 0.0428 0.0450 6.4 7.0 0.6 0.0012 0.052 8.4 0.8
±10.0 0.0075 0.0095 0.0117 815.4 1029.1 91.6 0.0005 2.077 1205.4 120.5
±5.0 0.0225 0.0245 0.0267 409.7 514.6 45.8 0.0010 1.791 602.7 60.3
±1.0 0.0225 0.0245 0.0267 85.1 102.9 9.2 0.0010 0.361 120.5 12.1
±0.1 0.0425 0.0445 0.0467 12.1 12.2 1.1 0.0015 0.060 14.5 1.4
0 to 10 0.0075 0.0095 0.0117 591.2 514.6 45.8 0.0005 1.807 602.7 60.3
0 to 5 0.0225 0.0245 0.0267 297.6 257.3 22.9 0.0010 1.656 301.4 30.1
0 to 1 0.0225 0.0245 0.0267 62.7 51.5 4.6 0.0010 0.334 60.3 6.0
0 to 0.1 0.0425 0.0445 0.0467 9.9 8.0 0.7 0.0015 0.057 9.6 1.0
Note: Accuracies are valid for measurements following an internal E Series Calibration. Averaged numbers assume dithering and averaging of 100 single-channel readings. Measurement accuracies are listed for
operational temperatures within ±1 °C of internal calibration temperature and ±10 °C of external or factory-calibration temperature. One-year calibration interval recommended. The Absolute Accuracy at Full Scale
calculations were performed for a maximum range input voltage (for example, 10 V for the ±10 V range) after one year, assuming 100 pt averaging of data. See overview on page 234 for example calculations.
PCI, AT, and DAQPadDAQCard
Absolute Accuracy
Nominal Range (V) % of Reading Temp Absolute Accuracy
Positive FS Negative FS 24 Hrs 90 Days 1 Year
Offset
(mV) Drift (%/°C) at Full Scale (mV)
10 -10 0.014 0.016 0.018 5.408 0.0002 7.208
10 0 0.014 0.016 0.018 2.966 0.0002 4.766
Note: Temp Drift applies only if ambient is greater than ±10 °C of previous external calibration. See page 234 for example calculations.
Table 3. NI 601xE Analog Output Accuracy Specifications.
Not on DAQCard-AI-16XE-50 Not on DAQCard-AI-16XE-50
Timing
PFI / Trigger
I/O Connector
3
RTSI Bus
PCI/PCMCIA/ISA/Parallel – I/O Channel
Digital I/O (8)
16-Bit
Sampling
A/D
Converter
EEPROM
Configuration
Memory
+
NI-PGIA
Gain
Amplifier
Calibration
Mux
Mux Mode
Selection
Switches
Analog
Muxes
Voltage
REF
Calibration
DACs
Trigger
Analog
Trigger
Circuitry
2
Trigger Level
DACs
6
Calibration
DACs
DAC0
DAC1
3
DAQ - STC
Analog Input
Timing/Control
Analog Output
Timing/Control
Digital I/O
Trigger
Counter/
Timing I/O
RTSI Bus
Interface
DMA/
Interrupt
Request
Bus
Interface
(8)
(8)
DAC
FIFO
8
Data (16)
AI Control
Data (16)
Analog
Input
Control
EEPROM
Control
DMA
Interface
MIO
Interface
DAQ-STC
Bus
Interface
Plug
and
Play
Analog
Output
Control
8255
DIO
Control
Bus
Interface
IRQ
DMA
Bus interface
DAQPnP
or MITE
AO Control
ADC
FIFO
Config.
Memory
Figure 1. NI 601xE Hardware Block Diagram
See page 233 in the E Series Multifunction DAQ
Overview for I/O connector diagrams.
See page 271 for more detailed specifications.